24/7 emergency line for break-ins and smashed glassCall 0800 088 6341

Doors and entrances

Fire and security doors

A fire door is a tested doorset that holds back fire for a set time, such as 30 minutes for FD30 or 60 minutes for FD60, while a security door is built and tested to resist forced entry. Some doorsets do both, when the test evidence covers the whole assembly.

Fire door with vision panel and panic bar

When is this the right choice?

You need these where a door protects an escape route, separates a shop from flats or a shared corridor, or guards a stockroom, cash office or rear exit. They suit owners acting on a fire risk assessment, landlords with mixed-use buildings and premises with a break-in history. A doorset only keeps its rating if frame, seals, glazing and hardware all match the test evidence.

What are the options?

FD30 and FD30S doorsetsThese give 30 minutes of fire resistance. The S means smoke seals are fitted to limit the spread of cold smoke.
FD60 doorsetsThese give 60 minutes of fire resistance where the fire strategy calls for a stronger division.
Fire-rated vision panelsFire-rated glass can be included if it is covered by the test evidence for that door.
Steel security doorsetsA steel leaf and frame with multi-point locking, tested to PAS 24 or LPS 1175 where the risk justifies it.
Panic and emergency exit hardwareBS EN 1125 panic bars suit doors used by the public, and BS EN 179 devices suit staff who know the building.

How much do fire and security doors cost?

Fire and security doors usually cost £895 to £2,495 ex VAT per door set, supplied and fitted. The rating, leaf size, vision panels, and lock or panic hardware set the price, and steel security doorsets cost more than timber fire doors. Altering a frame, making good the wall or matching existing finishes adds labour. We price each door against its test evidence.

Guide prices exclude VAT. Your written quote is fixed after survey.

What is the specification?

Fire testBS 476-22 (FD30, FD60) or BS EN 1634-1 (E30, E60 under BS EN 13501-2)
Smoke controlS suffix, as in FD30S, shows smoke seals are included
ClosersBS EN 1154, with power size 3 or above on fire doors
Exit hardwareBS EN 1125 panic bars or BS EN 179 emergency exit devices
SecurityPAS 24 doorsets, or LPS 1175 for rated security products
Typical lead time3 to 8 weeks from order (typical range)

How does the job run?

  1. Check the requirement

    We start from your fire risk assessment or security brief, and confirm the rating each door needs.

  2. Survey each door

    We record the size, frame, wall type and gaps, and note any signs that the existing door has been altered.

  3. Order a matched doorset

    Leaf, frame, seals, hinges and closer are ordered to match the test evidence.

  4. Fit and record

    The doorset is installed, gaps are checked, and you receive the details for your fire safety records.

Common questions

Does my shop legally need a fire door?

It depends on your layout and fire risk assessment. In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to keep people safe, which can mean fire doors on escape routes or between uses. Scotland and Northern Ireland have their own fire safety law.

Can I put a lock on a fire exit door?

You can, but it must open easily from the inside without a key while people are in the building. That is why panic bars to BS EN 1125 or emergency exit devices to BS EN 179 are used. Extra locks must never block escape during opening hours.

What is the difference between FD30 and FD60?

FD30 is tested to hold back fire for 30 minutes and FD60 for 60 minutes. An S suffix, as in FD30S, means the door also limits smoke. Your fire risk assessment or fire strategy sets the rating each door needs.

Can you fit a fire door into my existing frame?

Only if the test evidence allows it, and a full doorset is usually the safer route. Old frames may not be fire rated, and gaps or worn hinges can undo the rating. We check the opening and replace the frame, seals and hinges where needed.

How often should fire doors be checked?

Regularly, at intervals set by your fire risk assessment, with busy doors checked more often. Look for damaged seals, wide gaps, loose hinges and closers that no longer pull the door shut. Keep a written record, and have any damage put right by a competent person.

Which materials go with this?

Get my free quote

Free survey and a written fixed quote.

Choose the closest match.
Enter a UK postcode.
Enter your name.
Enter a UK phone number.
Enter your email address.

Talk to us about fire and security doors

Written quote, one contract, 10-year workmanship guarantee.

Call nowGet a quote